14.PMC CONTROL FUNCTION B-63783EN-1/01
- 1450 -
(15) Distribution end signal
DEN1<F66#6>, DEN2<F70#6>, ...
[Classification] Output signal
[Function] While movement along an axis is being made by a command from the
PMC, this signal state is 0. When movement is stopped, the signal is
set to 1. When execution of a move command is stopped by axis
control stop signal STPx, however, this signal is not set to 1.
DENo
o : 1 The first axis is in the stopped state.
2 The second axis is in the stopped state.
3 The third axis is in the stopped state.
: :
NOTICE
The signal DENx is set to 1 even if the actual motion
remains due to the acceleration/deceleration delay.
Therefore, in order to confirm that the axis has
actually stopped, use the In Position Signal (INPx) or
Axis Moving Signal (MVx) at the same time.
(16) Buffer full signal
BUF1<F66#5>, BUF2<F70#5>, ...
[Classification] Output signal
[Function] When there is a command block in the input buffer, this signal is set to
1.
BUFo
o : 1 There is a command block in the input buffer for the first axis.
2 There is a command block in the input buffer for the second axis.
3 There is a command block in the input buffer for the third axis.
: :