B-63783EN-1/01 2.PREAPARATIONS FOR OPERATION
- 303 -
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G064 *-L1 *+L1
The above address is the signal address for the first axis.
For the signal addresses for the second axis and subsequent axes, see
the address table in Appendix A.1.
Alarm and message
Number Message Contents
OT0007 + OVERTRAVEL ( HARD ) The stroke limit switch in the positive direction was triggered.
This alarm is generated when the machine reaches the stroke end.
When this alarm is not generated, feed of all axes is stopped during
automatic operation.
During manual operation, only the feed of the axis on which the alarm
occurred is stopped.
Clearing the alarm
1. When an invalid origin is set for the coordinate system
=> Correct the program.
2. When the program contains an error
=> Correct the program.
Manually move the movable parts of the machine in the opposite
direction (toward the safe side), such that they are well away from the
limit switch. Then, press the RESET button on the MDI panel.
OT0008 - OVERTRAVEL ( HARD ) The stroke limit switch in the negative direction was triggered.
This alarm is generated when the machine reaches the stroke end.
When this alarm is not generated, feed of all axes is stopped during
automatic operation.
During manual operation, only the feed of the axis on which the alarm
occurred is stopped.
Clearing the alarm
1. When an invalid origin is set for the coordinate system
=> Correct the program.
2. When the program contains an error
=> Correct the program.
Manually move the movable parts of the machine in the opposite
direction (toward the safe side), such that they are well away from the
limit switch. Then, press the RESET button on the MDI panel.
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN-1)
II-6.2 Over travel