B-63783EN-1/01 11.PROGRAM COMMAND
- 1157 -
2431 M code to execute external device subprogram calls
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 99999999
Set the M code to execute external device subprogram calls. When 0 is
set, M198 is used. M01, M02, M30, M98, and M99 cannot be used to
execute external device subprogram calls. When a negative number, 1,
2, 30, 98, or 99 is set for this parameter, M198 is used to execute external
device subprogram calls.
Alarm And message
Number Message Contents
PS0590 TH ERROR A TH error was detected during reading from an input
device.
The read code that caused the TH error and how many
statements it is from the block can be verified in the
diagnostics screen.
PS0591 TV ERROR An error was detected during the single-block TV error.
The TV check can be suppressed by setting TVC
parameter No. 0000#0 to "0".
PS0592 END OF RECORD The EOR (End of Record) code is specified in the middle of
a block.
This alarm is also generated when the percentage at the
end of the NC program is read.
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-12 Program configuration