13.MEASUREMENT B-63783EN-1/01
- 1398 -
1428 Skip function (G31) feedrate
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the feedrate for the skip function (G31). This parameter is valid
when SKF, a bit of parameter No. 1400, is set to 1, namely the skip
function feedrate is the value set in this parameter.
NOTE
See parameter Nos. 7211 to 7214 for multi-step and high-speed
skip.
#7 #6 #5 #4 #3 #2 #1 #0
7200 HSS
[Input type] Parameter input
[Data type] Bit
# 4
# 4 # 4
# 4 HSS
HSSHSS
HSS Specifies whether to use the high-speed skip signal when the skip
function or multi-step skip function is used.
0: Not used. (The skip signal of the conventional type is used.)
1: Used. (The skip signal of the conventional type is disabled.)
#7 #6 #5 #4 #3 #2 #1 #0
7300 SEB
[Input type] Parameter input
[Data type] Bit
# 7
# 7 # 7
# 7 SEB
SEBSEB
SEB Specifies whether to reflect the number of accumulated pulses due to
acceleration/deceleration and positional deviation when the skip signal is
turned on in skip operation.
0: Do not reflect.
1: Reflect for compensation.
The input position of the skip signal is found by reflecting the number of
accumulated pulses due to actual acceleration/deceleration and positional
deviation present when the skip signal is turned on. Namely, this is the
same as type B of FS15B. Note that there is no method equivalent to
type A (method of determination from a time constant and gain) of
FS15B.