B-63783EN-1/01 1.AXIS CONTROL
- 117 -
# 4
# 4 # 4
# 4 CCI
CCICCI
CCI Specifies the value to be used as the effective area during cutting feed
(cutting-feed effective area).
0: Uses parameter 1826, which is also used for rapid traverse.
1: Uses parameter 1838, which is used only for cutting feed.
When a positioning block is specified or an exact stop is specified in a
cutting feed block, the block decelerates the tool at the end of the block for
a position check. The cutting/rapid traverse position check function
allows the effective area (parameter 1838) to be set separately for cutting
feed in addition to the effective area (parameter 1826) for rapid traverse.
For example, a larger effective area can be set for rapid traverse, while an
ordinary small effective area is set for cutting feed. This can reduce
machining time (positioning time) without reducing machining precision.
The CCI bit (bit 4) of parameter 1800 is used to select whether this new
function or the standard position check function is used. When this
position check function is selected, it is effective for all axes. For axes
that do not require this function, set the same data in parameters 1826
and 1838.
When a rapid traverse block terminates a position check is performed
using the value set in rapid-traverse-specific parameter 1826. When a
cutting feed block terminates and the next block specifies cutting feed, a
position check is performed using the value set in cutting-specific
parameter 1838; if the next block specifies rapid traverse, however, a
position check is performed using the value in rapid-traverse-specific
parameter 1826. Furthermore, when a cutting feed block terminates,
cutting-specific parameter 1838 can always be used for a position check
regardless of the next block. This is specified by bit 5 of parameter 1800.
# 5
# 5 # 5
# 5 CIN
CINCIN
CIN When CCI is 1, the CIN bit specifies the condition under which the
cutting feed parameter defines the cutting-feed effective area.
0: Used only when the next block specifies cutting feed.
1: Always used regardless of the next block.
# 6
# 6 # 6
# 6 SAK
SAKSAK
SAK Specifies whether to change the state of the servo ready signal SA when
the VRDY OFF alarm ignore signal DVAL is 1 or when the VRDY OFF
alarm ignore signal for each axis, DVALn, is 1.
0: The servo ready signal SA changes to 0.
1: The servo ready signal SA retains its state of 1.