1.AXIS CONTROL B-63783EN-1/01
- 90 -
1846 Distance at which the second stage of smooth backlash compensation begins
[Input type] Parameter input
[Unit of data] Integer axis
[Valid data range] Detection unit
[Valid data range] 0 to 999999999
This parameter specifies the distance where the second stage of smooth
backlash compensation begins from a point where the direction of axis
movement is reversed for individual axes.
1847 Distance at which the second stage of smooth backlash compensation ends
[Input type] Parameter input
[Unit of data] Integer axis
[Valid data range] Detection unit
[Valid data range] 0 to 999999999
This parameter specifies the distance where the second stage of smooth
backlash compensation ends from a point where the direction of axis
movement is reversed for individual axes.
1848 Amount of the first stage of smooth backlash compensation
[Input type] Parameter input
[Unit of data] Integer axis
[Valid data range] Detection unit
[Valid data range] -9999 to 9999
This parameter specifies the amount of the first stage of smooth
backlash compensation for individual axes.