B-63783EN-1/01 1.AXIS CONTROL
- 89 -
#7 #6 #5 #4 #3 #2 #1 #0
1804 RBK
[Input type] Parameter input
[Unit of data] Bit axis
NOTE
Once this parameter is re-set, it is necessary to
switch the power off and on again.
# 6 RBK Specifies whether to perform cutting-/rapid traverse-specific backlash
compensation as follows:
0: Do not perform.
1: Perform.
#7 #6 #5 #4 #3 #2 #1 #0
5426 HPE
[Input type] Parameter input
[Unit of data] Bit axis
NOTE
Once this parameter is re-set, it is necessary to switch
the power off and on again.
# 3 HPE Specifies the actual detection unit for the output of interpolation-type
pitch error compensation, third-dimensional error compensation,
interpolation-type straightness compensation, and smooth backlash
compensation as follows:
0: Detection unit
1: 1/1000 of detection unit (the same unit as for nano interpolation)
NOTE
1 Even when this parameter is set to 1, the
measurement unit of already set compensation data
remains to be the detection unit. So, it is unnecessar
to change the compensation data.
2 Even when this function is enabled, the servo output
for the following functions remains to be in the
detection unit:
Stored pitch error compensation,
gradient compensation,
straightness compensation, and
128-point straightness compensation.