9.SPINDLE FUNCTION B-63783EN-1/01
- 776 -
5614 Data for adjusting the gain of the spindle speed analog output
[Input type] Parameter input
[Data type] Integerspindle
[Valid data range] 700 - 1250
Set data for adjusting the gain of the spindle speed analog output.
[Adjustment] Make adjustment by following the procedure explained below:
(1) Set the standard setting to 800.
(2) Specify the spindle speed at which the spindle speed analog output voltage is
maximized (10 V).
(3) Measure the output voltage.
(4) Set the value obtained from the following equation in the parameter.
(5) After setting the parameter, specify the spindle speed again at which the
spindle speed analog output voltage is maximized, then check that the output
voltage is 10 V.
800
(V) voltageMeasured
10(V)
Setting ×=
- Connecting a serial spindle control unit
#7 #6 #5 #4 #3 #2 #1 #0
5603 APW
[Input type] Parameter input
[Data type] Bitspindle
# 3
# 3 # 3
# 3 APW
APWAPW
APW Specifies whether to transfer parameter No. 3020 through No. 3031 or
parameter No. 3000 through 3393 from the CNC to the spindle amplifier
when a serial spindle is used.
0: Transfer parameter No. 3020 through No. 3031.
1: Transfer parameter No. 3000 through No. 3393.
Set 1 only for serial spindle adjustment.