B-63783EN-1/01 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 639 -
7.1.9 External Deceleration
General
These signals decelerate the feedrate of the control axes down to the
speed which has been set by parameter No. 1426 and 1427.
Signal
External deceleration signal
*+ED1<G64#2>, *+ED2<G68#2>, ...
*-ED1<G64#3>, *-ED2<G68#3>, ...
[Classification] Input signal
[Function] These signals are used to apply deceleration; provided for each
direction of each control axis; +/* indicates the direction, while the
signal number corresponds to the number of the controlled axis.
* x E D y
y : 1 ..... The 1st axis is decelerated.
2 ..... The 2nd axis is decelerated.
3 ..... The 3rd axis is decelerated.
:
x : + : The feed is decelerated in the plus (+) direction.
- : The feed is decelerated in the minus (-) direction.
[Operation] When a signal becomes "0", the corresponding axis decelerate to stop
in the specified direction.
If the specified feedrate is lower than the external deceleration feedrate,
the specified feedrate is assumed.
- Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G064 *-ED1 *+ED1
The above addresses are the signal addresses for the first axis.
For the signal addresses for the second axis and subsequent axes, see
the Appendix A.1.