7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL B-63783EN-1/01
- 620 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
2405 RSO FPR
[Input type] Parameter input
[Data type] Bit
# 6
# 6 # 6
# 6 FPR
FPRFPR
FPR Specifies whether the function for feed per rotation without a position
coder (the function for converting feed-per-rotation F into feed-per-
minute F) is used in the feed-per-rotation mode (G95).
0: Not used.
1: Used.
# 7
# 7 # 7
# 7 RSO
RSORSO
RSO Specifies whether spindle override is enabled when the function for feed-
per-rotation without a position coder (the function for converting feed-
per-rotation F into feed-per-minute F) is being used in the feed-per-
rotation mode (G95).
0: Disabled.
1: Enabled.
Caution
CAUTION
1 For feed per revolution, if the spindle speed is low,
the feedrate will be uneven. The lower the spindle
speed, the more uneven the feedrate.
2 Threading is performed according to the signal
returned from the position coder, even if the system
has been set up to use position-coder-less feed per
revolution.
In other words, position-coder-less feed per
revolution is not enabled for the threading
command.
3 When position-coder-less feed per revolution is
enabled, the following functions are also enabled:
- Feedrate override signal
- Spindle override signal
- Dry run signal
- Clamping of the maximum cutting feedrate on
each axis
- Dwell per revolution
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-5.3 Cutting feed