2.PREAPARATIONS FOR OPERATION B-63783EN-1/01
- 312 -
5223 Negative (-) direction coordinate of stored stroke limit 2 of each axis
[Input type] Setting input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table(A))
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the coordinate in the negative-direction machine coordinate system
of stored stroke limit 2 for each axis.
Alarm and message
Number Message Contents
OT0003 + OVERTRAVEL ( SOFT 2 ) The tool entered the prohibited area of stored stroke check
2 during movement in the positive direction.
OT0004 - OVERTRAVEL ( SOFT 2 ) The tool entered the prohibited area of stored stroke check
1 during movement in the negative direction.
Caution
CAUTION
When the reference position return function is not
provided for an axis, no forbidden area is set for that
axis, so no forbidden-area alarm is generated for the
axis.
Note
NOTE
1 In setting a forbidden area, if the two points to be set
are the same, the area is as follows:
(1) When the forbidden area is stored stroke check
1, all areas are forbidden areas.
(2) When the forbidden area is stored stroke check
2 or stored stroke check 3, all areas are movable
areas.
2 Only the three basic axes can be specified in G22.
Reference item
Series15i/150i-MB
Operator’s Manual
(Operation)
(B-63784EN-1)
II-6.3 Stroke check