1.AXIS CONTROL B-63783EN-1/01
- 198 -
#7 #6 #5 #4 #3 #2 #1 #0
1803 MVB CLP ADJ
[Input type] Parameter input
[Data type] Bitaxis
# 1
# 1 # 1
# 1 ADJ
ADJADJ
ADJ Specifies the axis along which to move in adjustment mode in
synchronous control.
0: Axis along which to move in adjustment mode.
1: Not an axis along which to move in adjustment mode.
When this parameter is set to "1," the axis enters adjustment mode.
For an axis for which this parameter is set to "1," movement is performed
with a master axis move command.
Specify the bit for only one of the master and slave axes.
If a single master axis has multiple slave axes, set this bit to 1 for that
axis for which a synchronous error alarm is issued to recover the axis.
When alarms are issued for multiple axes, recover one axis, then change
this
arameter to recover another axis.
# 2
# 2 # 2
# 2 CLP
CLPCLP
CLP Specifies whether to compensate for synchronous error in synchronous
control.
0: Compensates for synchronous error.
1: Does not compensate for synchronous error.
(Set this bit only for the master axis.)
# 3
# 3 # 3
# 3 MVB
MVBMVB
MVB Specifies whether to validate a command to move the machine in the
direction of increasing the synchronous error in the adjustment mode.
0: Ignores the command.
1: Validates the command.
If a single master axis has multiple slave axes, reducing the synchronous
error on one axis by means of movement along the master axis may
result in increase in the synchronous error on another slave axis. When
this parameter is set to "0," the master axis cannot move in either
direction. Use ADJ (bit 1 of parameter No. 1803) to allow movement
alon
a slave axis, and
erform the a
ro
riate ad
ustment o
eration.