B-63783EN-1/01 2.PREAPARATIONS FOR OPERATION
- 337 -
Signal
Servo axis abnormal load detection signal AQSV<F155#3>
[Classification] Output signal
[Function] Notifies the PMC of an abnormal load detected on the servo axis.
[Output condition] This signal is set to 1 in the following case:
- When an abnormal load is detected on the servo axis, Cs axis,
spindle positioning axis, or spindle axis during rigid tapping
First spindle abnormal load detection signal AQSP1<F155#6>
[Classification] Output signal
[Function] Notifies the PMC of the detection of an abnormal load on the first
spindle.
[Output condition] This signal is set to 1 in the following case:
- When an abnormal load is detected on the first spindle subject to
speed control
Second spindle abnormal load detection signal AQSP2<F155#7>
[Classification] Output signal
[Function] Notifies the PMC of the detection of an abnormal load on the second
spindle.
[Output condition] This signal is set to 1 in the following case:
- When an abnormal load is detected on the second spindle subject
to speed control
Third spindle abnormal load detection signal AQSP3<F154#2>
[Classification] Output signal
[Function] Notifies the PMC of the detection of an abnormal load on the third
spindle.
[Output condition] This signal is set to 1 in the following case:
- When an abnormal load is detected on the third spindle subject to
speed control
Fourth spindle abnormal load detection signal AQSP4<F154#3>
[Classification] Output signal
[Function] Notifies the PMC of the detection of an abnormal load on the fourth
spindle.
[Output condition] This signal is set to 1 in the following case:
- When an abnormal load is detected on the fourth spindle subject
to speed control
The functions output the following alarms and signals:
Signal output Alarm
AQSV AQSPn
(n=1-4)
SV0409 SV0119/0120/
0127/0128
Servo axis
O
_
O
_
Cs contour control axis
O
_
O
_
Spindle positioning axis
O
_
O
_
Rigid tapping
O
__
O
Spindle axis under
speed control
_
O
_
O