B-63783EN-1/01 1.AXIS CONTROL
- 5 -
1021 Subscripts of the axis names of parallel, synchronization control, and
tandem control axes
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0-9, 65-90
To distinguish the axes controlled in parallel operation mode, synchronization
control mode, and tandem control mode, specify a suffix for each axis.
Setting Meaning
0 Set 0 for those axes not controlled in parallel
operation mode, synchronization control, or
tandem control.
1-9 A set number is used as a suffix.
65-90 A set alphabetic character (ASCII code) is used as
a suffix.
Example: For an axis whose axis name is X, the following will be indicated:
Setting Axis name indicated on screens such as
position display screen
0X
1X1
77 XM
83 XS
Note
NOTE
1 When the optional second auxiliary function is used,
those addresses that are specified in the second
auxiliary function cannot be used as axis names.
2 When the axis name extension function is used, the
second auxiliary function cannot be used.
Reference item
Series15i/150i-MB
Operator’s Manual
(Programming)
(B-63784EN)
II-2.2 Axes name