5.AUTOMATIC OPERATION B-63783EN-1/01
- 540 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1000 EMI EHM
[Input type] Parameter input
[Data type] Bit
# 5
# 5 # 5
# 5 EHM
EHMEHM
EHM Specifies conditions when handle interruption is valid.
0: When in G01, G02, or G03 mode, handle interruption is valid during automatic
operation startup, stopping, and holding.
1: Handle interruption is only valid for G01, G02, and G03 blocks during
automatic operation startup.
# 6
# 6 # 6
# 6 EMI
EMIEMI
EMI Specifies validity of manual interrupts and manual setup operations
during simultaneous manual-automatic operation.
0: Manual interrupts are invalid and manual setup operations are valid.
1: Manual interrupts and manual setup operations are valid.
#7 #6 #5 #4 #3 #2 #1 #0
1200 MNS
[Input type] Parameter input
[Data type] Bit
# 2
# 2 # 2
# 2 MNS
MNSMNS
MNS Specifies whether to shift coordinate systems when data is written into
the system variables which specifies the distance to be caused by a
manual interrupt.
0: Shift all workpiece coordinate systems and local coordinate systems.
1: Do not shift any workpiece coordinate system or local coordinate system.
(This is the same operation as that specified by the "cancel" soft key on the
manual-interrupt-distance screen.)