B-63783EN-1/01 1.AXIS CONTROL
- 121 -
# 7
# 7 # 7
# 7 ACM
ACMACM
ACM Specify whether to use an optional command multiplication factor 1/N.
0: Does not use the factor.
1: Uses the factor.
This bit is effective only when an optional command multiplication factor
option is provided.
1820 Command multiplier for each axis (CMR)
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] See the following descriptions.
[Valid data range] See the following descriptions.
i) When CMR = 0.5 to 48
Set ACM (bit 7 of parameter No. 1816) to 0.
Then specify the value given by the following expression.
Setting = CMR*2
Valid range: 1 to 96
ii) When CMR = 1/2 to 1/27
(An optional command multiplier (option) is required)
Set ACM (bit 7 of parameter No. 1816) to 1.
Then specify the value given by the following expression.
Setting = 1/CMR
Valid range: 1 to 27
1821 Value of the numerator of a command multiplier for each axis (optional
command multiplier)
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 9999
Specify the value of the numerator of a command multiplier for each
axis. The optional command multiplier is required.
1822 Value of the denominator of a command multiplier for each axis (optional
command multiplier)
[Input type] Parameter input
[Data type] Integeraxis
[Valid data range] 0 - 9999
Specify the value of the denominator of a command multiplier for
each axis. The optional command multiplier is required. To use the
optional command multiplier n/m (n: 1821, m: 1822), set a value
other than 0 in parameter No. 1821 and No. 1822.