1) Two–path wait function
When an M code is specified for the NC and loader control of the
FANUC Series 16–TA, 16–TB, 18–TA, or 21–TB a two–path wait
can be executed.
D When a waiting M code is specified in the programs for the NC and
loader, either can wait for the other in the specified block.
D The M code must be specified in a single block as shown below:
M m
;
m: Waiting M code number
2) Three–path wait function (for the Series 16/18)
A system featuring a two–path (TT) NC and loader control can use
a three–path wait function.
The range of three–path waiting M codes is specified in the main and
loader parameters (parameters 8110 and 8111) in the same way as the
range of two–path waiting M codes is specified.
D A wait pattern is specified after address P in the same block as the
waiting M code. Address P is used to distinguish a three–path wait
from a two–path wait.
D The M code must be specified in a single block, as shown below:
M m
P p ;
m: Waiting M code number
p : Number specifying a wait pattern
D Table 3.4.1 lists address–P values and their meanings:
Table 3.4.1
Meaning
Address P Wait pattern
(Not used)
Bits 7 to 3
Loader
Bit 2
SUB
Bit 1
MAIN
Bit 0
P3 MAIN–SUB wait 00000 0 1 1
P5 MAIN–loader wait 00000 1 0 1
P6 SUB–loader wait 00000 1 1 0
P7 MAIN–SUB–loader wait 00000 1 1 1
When the wait ignore signal (G1063.7) of tool post 2 is set to 1 and M101
to M103 are specified as waiting M codes
Parameter setting : Parameter 8110 = 101
Parameter 8111 = 103
4.4
LOADER CONTROL
FUNCTIONS
4.4.1
Multipath Wait
Function with M Code
(T Series Only)
D Overview
Examples