4. OPERATION
B–62443EN–2/03
130
0 : 96 communication signals (G/F0212 to G/F0219
and G/F0252 to G/F0255).
1 : 192 communication signals.
NOTE
1 For this parameter setting to take effect, the power must be
turned off then back on.
2 Only the loader supports this parameter.
When the loader control function is provided, a loader control selection
signal is added to the standard CNC–PMC interface. The loader control
selection signal is similar to the HEAD signal of the 16–TTA or 18–TTA.
The signal switches the object of the CRT display or MDI operation
between the loader and NC.
Loader control selection signal (Only the NC (machine) supports this
signal.)
LCBS
<G0251, bit 1>
[Classification] Input signal
[Function] Switches the object of CRT display or MDI operation
between the loader and NC.
[Operation] 0 : NC (machine) is subjected to the CRT display or
MDI operation.
1 : Loader control is subjected to the CRT display or
MDI operation.
#7 #6 #5 #4 #3 #2 #1 #0
No.
G251 LCBS
This function has no related parameters.
This function has no related alarms.
NOTE
1 When LCBS is set to 1, the object of CRT display or MDI
operation can be switched to the loader or NC by holding
down <SHIFT> on the MDI panel and pressing <HELP>.
2 Only the NC (machine) PMC supports the loader control
selection signal (LCBS).
4.4.4
Loader Control
Selection Signal
D Overview
D Explanation
D Parameter