8. AUXILIARY FUNCTION
B–63523EN–1/03
976
[Classification] Output signal
[Function] These signals report particular miscellaneous functions are specified. The
miscellaneous functions in a command program correspond to output
signals as indicated below.
Command program Output signal
M00
M01
M02
M30
DM00
DM01
DM02
DM30
[Output condition] A decode M signal goes “1” when:
· The corresponding miscellaneous function is specified, and any move
commands and dwell commands specified in the same block are
completed. These signals are not output when the end signal of the
miscellaneous function is returned before completion of such move
commands and dwell commands.
A decode M signal goes “0” when:
· The FIN signal goes “1”
· Reset occurs
[Classification] Output signal
[Function] These signals report that spindle speed functions have been specified.
[Output condition] For the output conditions and procedure, see the description of “Basic
procedure” above.
[Classification] Output signal
[Function] These signals report that tool functions have been specified.
[Output condition] For the output conditions and procedure, see the description of “Basic
procedure” above.
Decode M signals
DM00 <F009#7>,
DM01 <F009#6>,
DM02 <F009#5>,
DM30 <F009#4>
Spindle–speed code
signals S00 to S31
<F022–F025>
Spindle–speed strobe
signal SF <F007#2>
Tool function code
signals T00 to T31
<F026–F029>
Tool function strobe
signal TF <F007#3>