B–63523EN–1/03
1. AXIS CONTROL
113
Example)
Controlled
axis
Connector
number for
first sepa-
rate detector
interface
unit
Connector
number for
second sep-
arate detec-
tor interface
unit
No.1936 No.1937
No.1905
(#7, #6)
X 1 Not used 0 0 0,1
Y Not used 2 0 1 1,0
Z Not used 1 0 0 1,0
A Not used Not used 0 0 0,0
B 2 Not used 1 0 0,1
C Not used 3 0 2 1,0
If the FSSB setting mode is automatic setting (bit 0 of parameter No. 1902
= 0), this parameter is set automatically when data is entered using the
FSSB setting screen. For manual setting 2 (bit 0 of parameter No. 1902
= 1), the user must set this parameter.
Number Message Description
456 ILLEGAL CURRENT
LOOP
The current control cycle settings (pa-
rameter No. 2004, bit 0 of parameter
No. 2003, and bit 0 of parameter No.
2013) are incorrect. Possible problems
are as follows.
– For the two axes whose servo axis
numbers (settings of parameter No.
1023) are an odd number followed
by an even number (a pair of axes
1 and 2 or axes 5 and 6, for exam-
ple), a different current control cycle
is set for each of the axes.
– The requirements for slaves need-
ed for the set current control cycle,
including the number, type, and
connection method of them, are not
satisfied.
457 ILLEGAL HI HRV (250US) Use of high–speed HRV is specified al-
though the current control cycle is 200
µs.
458 CURRENT LOOP
ERROR
The current control cycle setting does
not match the actual current control
cycle.
459 HI HRV SETTING
ERROR
For the two axes whose servo axis num-
bers (settings of parameter No. 1023) are
an odd number followed by an even
number (a pair of axes 1 and 2 or axes 5
and 6, for example), the SVM for one of
the axes supports high–speed HRV con-
trol but the SVM for the other does not.
Refer to the SVM specification.
Alarm and message
D Servo alarms