B–63523EN–1/03
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
836
[Classification] Output signal
[Function] Indicates that the system is set to high–precision contour control mode
(HPCC mode).
[Output condition] The signal is set to 1 if G05 P10000 (HPCC mode ON) is specified in a
program. The signal is set to 0 if G05 P0 is specified in a program or if
HPCC mode is canceled by a reset.
[Classification] Output signal
[Function] Indicates that the system is operating in high–precision contour control
mode (HPCC operation is in progress).
[Output condition] The signal is set to 1 if G05 P10000 (HPCC mode ON) is specified in a
program and if specifiable data of except G00, M, S, T, B is executed.
The signal is set to 0 when:
(1)Automatic operation is halted.
(2)Automatic operation is stopped.
(3)Specifiable data of G00, M, S, T or B is executed.
(4)HPCC mode is canceled.
For the specifiable date, refer to 7.1.14.
#7 #6 #5 #4 #3 #2 #1 #0
F066 EXHPCC MHPCC
7.1.14.3
Signal
HPCC mode signal
MHPCC <F066#6>
HPCC operation signal
EXHPCC <F066#7>
Signal addresses