13. INPUT/OUTPUT OF DATA
B–63523EN–1/03
1716
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is EVAR <G098#5/G251#5>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
[Classification] Output signal
[Function] This signal notifies the Power Mate that the input/output data consists of
parameters.
[Output condition] This signal is set to 1 in the following case:
– When the input/output data consists of parameters, and data
input/output has been started
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is EPARM <G098#6/G251#6>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
[Classification] Output signal
[Function] This signal notifies the Power Mate that input/output data consists of
diagnostic (PMC) data.
[Output condition] This signal is set to 1 in the following case:
– When input/output data consists of diagnostic (PMC) data, and data
input/output has been started
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is EDGN <G098#7/G251#7>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
Slave parameter
selection signal
EPARM <F177#6>
Slave diagnostic data
selection signal
EDGN <F177#7>