12. DISPLAY/SET/EDIT
B–63523EN–1/03
1616
Pressing the [INIT] soft key and then the [EXEC] soft key initializes a
cursor–selected item with a standard parameter. Pressing the [G_INIT]
soft key and then the [EXEC] soft key initializes all items of a
cursor–selected parameter set (velocity–first or precision–first). (Also
this operation is usable only when PWE = 1.)
The following table lists the initial values.
Initial values
Item Velocity–
first (LV1)
Precision–
first (LV10)
Unit
Pre–interpolation acceleration/
deceleration rate
4902.000 1042.000 mm/sec
2
Bell–shaped acceleration change
time
32 64 msec
Allowable acceleration change 0 0 mm/sec
2
Post–interpolation acceleration/
deceleration time constant
24 24 msec
Corner feedrate difference 1000 400 mm/min
Maximum allowable cutting
feedrate
10000 10000 mm/min
On this screen, it is possible to select a precision level at the midpoint
between the velocity–first parameter setting (precision level 1) and the
precision–first parameter setting (precision level 10). As shown below,
the level changes linearly between the two extreme points. Selecting a
level between them can set up an optimum parameter.
1 6 10
Effective value
Precision level
Precision level select
screen