11. PROGRAM COMMAND
B–63523EN–1/03
1368
7) Input to FROM and output from FROM
The ”INMC” file for the embedded macro stored in FROM can be
input and output to the memory card by BOOT SYSTEM. Please refer
to the maintenance manual for the details.
8) Common variables #200 – #499
Common variables #200 – #499 can be used by this function. The
treatment of these variables is similar to #100 – #149 (– #199).
(1)Common variables #200 – #499 are initialized and become
<empty> when the power supply is turned off.
(2)When embedded macro data is reloaded by the softkey
[RELOAD], common variables #200 – #499 become <empty>.
(3)When parameter PV5 (No.6001#3) is 1, common variables #200
– #499 can be outputted same as #100 – and #500 –.
(4)When parameter CCV (No.6001#6) is 1, common variables #200
– #499 are cleared to <empty> by reset same as #100 –. When CCV
is 0, they are not cleared by reset.
(5)Common variables #200 – #499 can not be read and written from
the window function.
9) Series / Edition
The embedded macro file can manage by the series and edition. It is
possible to set the four digits number to the parameter No.12015 as the
series and the four digits number to the parameter No. 12016 as the
edition. And this series / edition can be stored by the [SAVE] operation
of the embedded macro data. The series / edition of the embedded
macro file is displayed at the right of ”EMBED MCR” of the system
configuration screen. The embedded macro function can not be used
when ”EMBED MCR” is not displayed, and when the series / edition
is not displayed, the series / edition is not set or the state that there is
no ”INMC” file in FROM.
D New making (1)
1) Do the program all clear operation. (”O–9999”+[DELETE])
2) Decide the embedded macro programs Nos. and input the decided
programs Nos. to the parameter No.12011 and 12012.
3) Enable to edit the embedded macro programs. (Parameter
No.12010 =2)
4) Decide the calling G–codes and the calling macro program
numbers for embedded macro programs and input to parameter No.
12020 to 12049.
5) Edit the embedded macro programs.
6) Decide the treatment of edited embedded macro programs (edit /
reference enable) and input to parameter No.12010.
7) Decide the series and edition, and input to parameter No.12015 and
12016.
8) Decide the password and input to parameter No.12013.
9) Do the writing from DRAM to FROM operation.
Embedded macro
program making
procedure