B–63523EN–1/03
1. AXIS CONTROL
146
Units digit in the parameter for the first axis
→ Set the axis number for the master axis when the first axis is used
as a slave axis.
Tens digit in the parameter for the first axis
→ Set the axis number for the master axis when the second axis is used
as a slave axis.
Units digit in the parameter for the second axis
→ Set the axis number for the master axis when the third axis is used
as a slave axis.
Tens digit in the parameter for the second axis
→ Set the axis number for the master axis when the fourth axis is used
as a slave axis.
Units digit in the parameter for the third axis
→ Set the axis number for the master axis when the fifth axis is used
as a slave axis.
Tens digit in the parameter for the third axis
→ Set the axis number for the master axis when the sixth axis is used
as a slave axis.
Units digit in the parameter for the fourth axis
→ Set the axis number for the master axis when the seventh axis is
used as a slave axis.
Tens digit in the parameter for the fourth axis
→ Set the axis number for the master axis when the eighth axis is used
as a slave axis.
Number Tens digit Units digit
First
Second
Third
Fourth
Second axis
Fourth axis
Sixth axis
Eighth axis
First axis
Third axis
Fifth axis
Seventh axis
NOTE
The axis number settings are: 0 for the first axis, 1 for the
second axis, 2 for the third axis, and so on.
Example) To set the 3rd axis as the master axis and the 4th axis to the slave
axis, set as follows:
No. 8311
1st axis 00
2nd axis 20
3rd axis 00
4th axis 00
8312 Enabling/disabling mirror image in synchronous control
[Data type] Byte axis
[Valid data range] –127 to +128
This parameter sets the mirror image function. When 100 or a greater
value is set with this parameter, the mirror image function is applied to
synchronous control. Set this parameter to the slave axis.