B–63523EN–1/03
12. DISPLAY/SET/EDIT
1595
#7
6350
#6 #5 #4
FTA
#3 #2
FTM
#1
TQ2
#0
TQ1
[Data type] Bit
TQ1, TQ2 The store interval for the fine torque sensing function is set.
TQ1 TQ2 Store interval
0 0 8ms
0 1 16ms
1 0 32ms
1 1 Invalid (P/S5199)
FTM The function of saving stored disturbance load torque data as sample data
is:
0 : Disabled.
1 : Enabled.
FTA This bit specifies whether to match the detection level on the torque
monitor screen with the threshold value of the abnormal load detection
alarm (parameter No. 2104 or 4341).
0 : The detection level is not matched with the threshold.
1 : The detection level is matched with the threshold.
When this bit is set to 1, pressing the [END] soft key after changing the
detection level on the torque monitor screen reflects the detection level
in parameter No. 2104 (servo motors) or No. 4341 (spindle motors).
(The abnormal load detection function is optional.)
NOTE
Even when the setting of parameter No. 2104 or 4341 is
changed by MDI or other means, the detection level on the
torque monitor screen remains unchanged.
6360 Target axis 1 for fine torque sensing
6361 Target axis 2 for fine torque sensing
6362 Target axis 3 for fine torque sensing
6363 Target axis 4 for fine torque sensing
[Data type] Byte
[Valid data range] –4 to 8
These parameters specify target axes for the fine torque sensing function.
For a servo axis, specify a controlled–axis number from 1 to the number
of controlled axes. For a spindle axis, specify an axis number from –1 to
–(the number of controlled axes), where the sign of the axis number is
inverted. If an illegal axis number is set, the P/S5199 alarm is issued.
Parameter