B–63523EN–1/03
12. DISPLAY/SET/EDIT
1551
The execution time of a program is displayed on the program machine
time display screen. The machine time can be displayed, in hours,
minutes, and seconds format, for up to 10 main programs.
The time between the first start operation after a reset in memory
operation mode, until another reset is performed, is counted. When no
reset is performed, the time from the start of operation until M02 (M30)
is encountered is counted. The time in a stop state is not counted. The time
for completion of an M, S, T, or B function is counted.
The displayed machining time can be inserted (stamped) as a comment
in a program stored in memory. The machining time is placed as a
comment after the program number.
The machining time located after a program number can be displayed on
the program directory screen (by setting bit 0 (NAM) of parameter No.
3107 to 1). Using this screen, the user can determine the machining time
required for each program.
#7 #6 #5 #4 #3 #2 #1 #0
3107 NAM
[Data type] Bit
NAM Program list
0 : Only program numbers are displayed.
1 : Program numbers and program names are displayed.
#7 #6 #5 #4 #3 #2 #1 #0
3404 M02
[Data type] Bit
M02 When M02 is specified in memory operation
0 : M02 is sent to the machine, and the head of the program is
automatically searched for. So, when the end signal FIN is returned
and a reset or reset and rewind operation is not performed, the
program is executed, starting from the beginning.
1 : M02 is sent to the machine, but the head of the program is not searched
for. (The head of the program is searched for by the reset and rewind
signal.)
12.1.14
Stamping the
Machining Time
General
Parameter