B–63523EN–1/03
18. TROUBLE DIAGNOSIS
1995
When Soft key [G–ADJ.] is pressed, the following soft keys appear.
[<][][][][] [] []
W.PRM G–ADJ. TRB_LV (OPRT)
[<][][][][][] [>]
TIME→ TIME← H–DOBL H–HALF (OPRT)
[<][][][][][] [>]
CH–1↑ CH–1↓ V–DOBL V–HALF (OPRT)
[<][][][][][] [>]
CH–2↑ CH–2↓ V–DOBL V–HALF (OPRT)
[TIME→]: Shift the waveform rightward.
[TIME←]: Shift the waveform leftward.
[H–DOBL]: Double the time scale of the waveform
[H–HALF]: Half the time scale of the waveform
[V–DOBL]: Double the height scale of the waveform
[V–HALF]: Half the height scale of the waveform
[CH–1↑]: Shift the zero point upward
[CH–1↓]: Shift the zero point downward
[CH–2↑]: Shift the zero point upward
[CH–2↓]: Shift the zero point downward
The time scale is a common scale for the channel 1 and 2.
The position and magnification of the height scale can be set for each
channel.
Operation
Change of position and
magnification