PREFACE
B–63523EN–1/03
p–4
One address accommodates eight signals.
#7 #6 #5 #4 #3 #2 #1 #0
OPF000 SA STL SPL RWD
Symbol (#0 to #7 indicates bit position)Address
In an item where both T series and M series are described, some signals
are covered with shade (
) in the signal address figure as shown
below. This means either T series or M series does not have this signal.
Upper part is for T series and lower part is for M series.
[Example 1]
Signal EXLM, ST is a common signal, STLK is for T series only and
RLSOT and RVS are for M series only.
T series
M series
STLKRLSOT
#0
RVS
#7
G007
#6
EXLM
#2
ST
#1
Parameters are classified by data type as follows :
Dta type Valid data range Remarks
Bit
Bit axis
Byte
In some parameters, signs are ig-
nored.
Byte axis
0 to 255
In some parameters, signs are ig-
nored.
Word
–32768 to 32767
0 to 65535
Word axis
0 to 65535
2–word
2–word axis
99999999
NOTE
1 For the bit type and bit axis type parameters, a single data
number is assigned to 8 bits. Each bit has a different
meaning.
2 The axis type allows data to be set separately for each
control axis.
3 The valid data range for each data type indicates a general
range. The range varies according to the parameters. For
the valid data range of a specific parameter, see the
explanation of the parameter.
D Expression of signals
Parameter description