B–63523EN–1/03
3. MANUAL OPERATION
506
1423 Feedrate in manual continuous feed (jog feed) for each axis
[Data type] Word axis
(1)In M series, or in T series when JRV, bit 4 of parameter No. 1402, is
set to 0 (feed per minute), specify a jog feedrate at feed per minute with
an override of 100%.
Increment system Unit of data Valid data range
Millimeter machine 1 mm/min
Inch machine 0.1 inch/min
Rotation axis 1 deg/min
(2)When JRV, bit 4 of parameter No. 1402, is set to 1 (feed per revolution)
in T series, specify a jog feedrate (feed per revolution) under an
override of 100%.
Increment system Unit of data Valid data range
Millimeter machine 0.01 mm/rev
Inch machine 0.001 inch/rev
Rotation axis 0.01 deg/rev
#7
7100
#6 #5
MPX
#4 #3 #2 #1
THD
#0
JHD
[Data type] Bit
JHD Manual handle feed in JOG mode or incremental feed in the manual
handle feed
0 : Invalid
1 : Valid
THD Manual pulse generator in TEACH IN JOG mode
0 : Invalid
1 : Valid
MPX Specifies how the manual handle feed travel distance select signals are to
be used as follows:
0 : The signals (MP1 and MP2; bits 4 and 5 of G019) for the first manual
pulse generator are used for the first to fourth (F series) or third (T
series) pulse generators in common.
1 : Each manual handle feed travel distance select signal is used for an
individual manual pulse generator.
First manual pulse generator: MP1, MP2 (G019#4, G019#5)
Second manual pulse generator: MP21, MP32 (G087#0, G087#1)
Third manual pulse generator: MP31, MP32 (G087#3, G087#4)
Fourth manual pulse generator: MP41, MP42 (G087#6, G087#7)
NOTE
Parameter MPX (bit 5 of No. 7100) is valid only in the Series
20i.
[Valid data range]
[Unit of data]
[Valid data range]
[Unit of data]