B–63523EN–1/03
1. AXIS CONTROL
144
[Classification] Input signal
[Function] synchronous control is performed in jog, handle, or incremental feed
mode.
The signal is provided for each controlled axis. The number at the end
of the signal name represents the number of the controlled axis.
1. ... The first axis becomes the slave axis for synchronous control.
2. ... The second axis becomes the slave axis for synchronous control.
3. ... The third axis becomes the slave axis for synchronous control.
:
:
SYNCJ 1
[Operation] When the signal is set to 1, the control unit operates as described below:
– In jog, handle, or incremental feed mode, the control unit supplies the
move command, specified for the master axis, to both the master and
slave axes of synchronous control.
The master axis is specified with a parameter.
#7 #6 #5 #4 #3 #2 #1 #0
SYNC8G138 SYNC7 SYNC6 SYNC5 SYNC4 SYNC3 SYNC2 SYNC1
#7 #6 #5 #4 #3 #2 #1 #0
SYNC8G138 SYNC7 SYNC6 SYNC5 SYNC4 SYNC3 SYNC2 SYNC1
SYNCJ8G140 SYNCJ7 SYNCJ6 SYNCJ5 SYNCJ4 SYNCJ3 SYNCJ2 SYNCJ1
<M series>
Signals for selecting the
manual feed axis for
simple synchronous
control
SYNCJ1 to SYNCJ8
<G140>
Signal address
T series
M series