B–63523EN–1/03
13. INPUT/OUTPUT OF DATA
1725
G067#7
(HCREQ)
F061#3
(HCEXE)
G067#6
(HCABT)
F061#2
(HCAB2)
Fig. 13.9 (b) Time chart when screen hard copy is interrupted
CAUTION
1 Even when hard copy operation is performed for screens on
the second path side or loader control board side, the input
signals related to the screen hard copy function must
always be on the first path side. Hard–copy–related signals
on the second path or loader control board side are not
referenced.
2 Hard–copy–related output signals are all output to the first
path side. These signals are not output to the second path
and loader control board sides.
3 Even when the hard copy stop request acceptance signal
(HCAB2, F063#2) is 1, another hard copy operation can
start. In this case, HCAB2 is set to 0 automatically.
4 Even when the hard copy in–progress signal (F061#3) is set
from 1 to 0 (hard copy operation is terminated for a cause),
the next hard copy operation does not start unless G067#7
(HDCPY) is set to 0 once.
#7
HCREQG67
#6
HCABT
#5 #4 #3 #2 #1 #0
#7
F61
#6 #5 #4 #3
HCEXE
#2
HCAB2
#1 #0
Signal Address