B–63523EN–1/03
13. INPUT/OUTPUT OF DATA
1691
NOTE
1 If a value beyond the valid data range is specified, the
number of the input program is registered.
2 When the eight–digit program number function is not
provided, the program number should not be set in this
parameter but in parameter 3218.
Number Message Description
123 CAN NOT USE MACRO
COMMAND IN DNC
Macro control command is used during
DNC operation.
Modify the program.
210 CAN NOT COMAND
M198/M99
M198 and M99 are executed in the
schedule operation. M198 is executed
in the DNC operation. Modify the pro-
gram.
222 DNC OP. NOT ALLOWED
IN BG–EDIT
Input and output are executed at the
time in background edit.
Execute a correct operation.
NOTE
1 M198 (file access) cannot be executed in the input, output
and run simultaneous mode. An attempt to do so results in
P/S alarm No. 210.
2 A macro control command cannot be executed in the input,
output and run simultaneous mode. An attempt to do so
results in P/S alarm No. 123.
3 If an alarm condition occurs during the input, output and run
simultaneous mode, a block being processed when the
alarm condition occurs and all blocks before that are input
or output.
4 In the output and run simultaneous mode, if a device used
is a floppy disk drive or FA card, the file name is the
execution program number.
5 When a program is being executed in the output and run
simultaneous mode, if a subprogram is called, only the main
program is output.
Alarm and message
Note