4. REFERENCE POSITION ESTABLISHMENT
B–63523EN–1/03
540
#7
1002
#6 #5 #4 #3 #2 #1 #0
JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in JOG feed, manual rapid
traverse and manual reference position return
0 : 1 axis
1 : 3 axes
#7
1005
#6 #5 #4 #3 #2 #1 #0
ZRNx
[Data type] Bit axis
ZRNx When a command specifying the movement (except for G28) is issued in
automatic operation (MEM, RMT, or MDI) before referencing is
completed (after power on)
0 : An alarm is generated. (P/S alarm 224).
1 : No alarm is generated.
#7
1006
#6 #5
ZMIx
#4 #3 #2 #1 #0
NOTE
When this parameter is changed, you must power down the
control before continuing.
[Data type] Bit axis
ZMIx The direction of reference position return
0 : Positive direction
1 : Negative direction
#7
1201
#6 #5 #4 #3 #2
ZCL
#1
ZPI
#0
ZPR
[Data type] Bit
ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0 : Not set automatically
1 : Set automatically
ZPI Coordinates at the reference position when a coordinate system is set
automatically
0 : Value set in parameter No. 1250 is used.
1 : For input in mm, the value set in parameter 1250 is used, or for input in
inches, the value set in parameter No. 1251 is used.
ZCL Local coordinate system when the manual reference position return is
performed
0 : The local coordinate system is not canceled.
1 : The local coordinate system is canceled.
Parameter