B–63523EN–1/03
3. MANUAL OPERATION
466
NOTE
The JVi signals also serve as the override signals during dry
run in automatic operation mode.
[Classification] Input signal
[Function] Selects a rapid traverse rate for jog feed or incremental feed.
[Operation] When the signal turns to “1”, the control unit operates as described below:
D The control unit executes the jog feed or incremental feed at a rapid
traverse rate. The rapid traverse override is validated.
D When the signal is switched from “1” to “0” or vice versa during jog feed
or incremental feed, the feedrate is decelerated until it reaches zero, then
increased to the specified value. During acceleration and deceleration,
the feed axis and direction selection signal can be kept “1”.
Rapid traverse
rate
Jog feed mode
or incremental feed mode
+J1
RT
1st axis move
Feedrate selected by manual
feedrate override signal
WARNING
After the power is turned on, the stroke limit function does not
work until the reference position return is completed. During
this period, the control unit ignores the RT signal, if it is set to
“1”, and keeps moving the tool at a feedrate selected by the
manual feedrate override signal. The parameter RPD (No.
1401#0) can be set so the rapid traverse is validated before
the reference position return is completed.
#7
*JV7G010
#6
*JV6
#5
*JV5
#4
*JV4
#3
*JV3
#2
*JV2
#1
*JV1
#0
*JV0
*JV15G011 *JV14 *JV13 *JV12 *JV11 *JV10 *JV9 *JV8
RTG019
+J8G100 +J7 +J6 +J5 +J4 +J3 +J2 +J1
–J8G102 –J7 –J6 –J5 –J4 –J3 –J2 –J1
Manual rapid traverse
selection signal
RT<G019#7>
Signal address