B–63523EN–1/03
13. INPUT/OUTPUT OF DATA
1719
Setting Description
0, 1 RS–232–C serial port (connector JD36A on motherboard)
2 RS–232–C serial port (connector JD36B on motherboard)
3 Remote buffer interface (connector JD28A (RS–232–C interface) or
connector JD6A (RS–422 interface) on serial communication board)
4 Memory card interface
5 Data server interface
DNC1/DNC2 interface, OSI–Ethernet
DNC1 interafce #2
11 DNC1 interafce #2
Group 0
22
Group 2
Data is transferred between the CNC and Power Mate
in group n (n: 0 to 15) via the FANUC I/O Link.
34
|
Group 14
in group n (n: 0 to 15) via the FANUC I/O Link.
35
Group 15
NOTE
An input/output device can also be selected using the
setting screen. Usually the setting screen is used.
8760 Program number for data registration (data input/output function using the I/O link)
[Data type] Word
[Valid data range] 0 to 9999
When the data input/output function using the I/O link is used, this
parameter sets the program numbers of the programs to be used for
registering data (parameters, macro variables, and diagnostic data) from
Power Mates.
For a Power Mate in group n, the following program numbers are used:
For parameters: Setting + n 10 + 0
For macro variables: Setting + n 10 + 1
For diagnostic data: Setting + n 10 + 2
Example: When 8000 is set
8000: Parameters of group 0 (I/O channel = 20)
8001: Macro variables of group 0 (I/O channel = 20)
8002: Diagnostic data of group 0 (I/O channel = 20)
8010: Parameters of group 1 (I/O channel = 21)
8011: Macro variables of group 1 (I/O channel = 21)
8012: Diagnostic data of group 1 (I/O channel = 21)
8020: Parameters of group 2 (I/O channel = 22)
8021: Macro variables of group 2 (I/O channel = 22)
8022: Diagnostic data of group 2 (I/O channel = 22)
8150: Parameters of group 15 (I/O channel = 35)
8151: Macro variables of group 15 (I/O channel = 35)
8152: Diagnostic data of group 15 (I/O channel = 35)