B–63523EN–1/03
2. PREPARATIONS FOR OPERATION
441
The German VDE safety standard requires that the motor be deactivated
when the safety guard is opened. By using the VRDY OFF Alarm Ignore
signal, however, the CNC can be restarted without resetting, even if the
safety guard has been opened.
[Classification] Input signal
[Function] Disables the detection of servo alarm No. 401, VRDY OFF, for all axes.
[Operation] When this signal is set to logical 1, the control unit operates as follows:
@ The control unit does not issue servo alarm No. 401, VRDY OFF, even
when the servo amplifier ready signal goes off. The control unit,
however, sets servo ready signal SA to 0. The SA signal can remain set
to 1, depending on the setting of SAK, bit 6 of parameter No. 1804.
[Classification] Input signal
[Function] Disables the detection of servo alarm No. 401, VRDY OFF, for the
corresponding axis. These signals correspond to the controlled axes. The
suffixed number of each signal corresponds to the number of the
controlled axis.
[Operation] When this signal is set to logical 1, the control unit operates as follows:
@ The control unit does not issue servo alarm No. 401, VRDY OFF, even
when the servo amplifier ready signal for the corresponding axis goes
off. The servo ready signal SA, however, is set to 0. The SA signal,
however, can remain set to 1 depending on the setting of SAK, bit 6 of
parameter No. 1804.
2.9
VRDY OFF ALARM
IGNORE SIGNAL
General
Signal
All–Axis VRDY OFF
Alarm Ignore Signal
IGNVRY<G066#0>
Each–Axis VRDY OFF
Alarm Ignore Signal
IGVRY1 – IGVRY8
<G192>