B–63523EN–1/03
4. REFERENCE POSITION ESTABLISHMENT
549
[Data type] Bit axis
ZMIx The direction of reference position return and the direction of initial
backlash at power–on
0 : Positive direction
1 : Negative direction
#7
1201
#6 #5 #4 #3 #2
ZCL
#1
ZPI
#0
ZPR
[Data type] Bit
ZPR Automatic setting of a coordinate system when the manual reference
position return is performed
0 : Not set automatically
1 : Set automatically
ZPI Coordinates at the reference position when a coordinate system is set
automatically
0 : Value set in parameter No. 1250 is used.
1 : For input in mm, the value set in parameter 1250 is used, or for input in
inches, the value set in parameter No. 1251 is used.
ZCL Local coordinate system when the manual reference position return is
performed
0 : The local coordinate system is not canceled.
1 : The local coordinate system is canceled.
1240
Coordinate value of the reference position on each axis
in the machine coordinate system
NOTE
After setting this parameter, turn the power off then on again
so that the setting will take effect.
[Data type] Two–word axis
Increment system IS–A IS–B IS–C Unit
Millimeter machine 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] –99999999 to 99999999
Set the coordinate values of the reference positions in the machine
coordinate system.
1250
Coordinate value of the reference position used when automatic
coordinate system setting is performed
[Data type] Two–word axis
[Unit of data]