B–63523EN–1/03
3. MANUAL OPERATION
524
[Classification] Input signal
[Function] Sets a factor by which to multiply the least input increment to obtain the
unit to be used by the function of setting the stop position for jog feed.
[Operation] When the relevant feed axis direction selection signal is turned off, the
tool is controlled so that it stops at a position at which the coordinate value
is a round number in the specified units.
JGRD3 JGRD2 JGRD1 Factor
0 0 0 1 (invalid)
0 0 1 10 The absolute coordinate value after the tool stops is xxxxxxx0.
0 1 0 100 The absolute coordinate value after the tool stops is xxxxxx00.
0 1 1 1,000 The absolute coordinate value after the tool stops is xxxxx000.
1 0 0 10,000 The absolute coordinate value after the tool stops is xxxx0000.
1 0 1 100,000 The absolute coordinate value after the tool stops is xxx00000.
1 1 0 1 (invalid)
1 1 1 1 (invalid)
#7
G0201
#6 #5
JGRD3
#4
JGRD2
#3
JGRD1
#2 #1 #0
NOTE
1 This function is disabled in the alarm state.
2 This function cannot be used together with the ”least
command increment change function” for jog feed.
If the signals for both functions are input, the signal for the
”least command increment change function” is effective.
3 When the relevant feed axis direction selection signal <+J1
to +J8 or –J1 to –J8> is turned off while the tool is being
stopped by applying interlock in jog feed mode, this function
is disabled. For this reason, the tool is not fed to a position
at which the coordinate value is a round number even by
releasing interlock after that.
Signal
Signals for setting the
jog feed stop position
JGRD3 to JGRD1
<G201#5 to G201#3>
Signal address
Note