B–63523EN–1/03
1. AXIS CONTROL
41
5. If the current position starts at point e, passes across border P2, and
reaches point f, the high–speed position switch becomes OFF because
the passing direction is the same as defined (*2).
6. Even if the current position starts at point f, passes across border P1,
and reaches point g, the high–speed position switch does not change
its state (remains OFF) because the passing direction is opposite to the
defined direction (*1).
Signals are used to notify that the current position along an axis
corresponding to each high–speed position switch is within a range
specified by a parameter.
[Classification] Output signal
[Function] These signals are output if the current position along an axis
corresponding to each high–speed position switch satisfies a condition.
Up to 16 high–speed position switch signals can be output. This number
is the total of ordinary and direction–sensitive position switches.
The following table lists the relationships between the output addresses
for each high–speed position switch and parameters.
Relationships between direction–sensitive high–speed position switches and output addresses
Output
signal
address
Controlled
–axis
number
Output
type
switching
Enable/
disable
Maximum
operating
range
Effective
direction
for point A
Minimum
operating
range
Effective
direction
for point B
1st to 8th Value of
parameter
No. 8565
8570 to
8577
8508 8504 8580 to
8587
8512 8590 to
8597
8516
9th to 16th Value of
parameter
No. 8565
plus 1
8578 to
8579,
12201 to
12206
8509 8505 8588 to
8589,
12221 to
12226
8513 8598 to
8599,
12241 to
12246
8517
[Output condition] These signals are 1 in the following case:
· When the current position along the controlled axis is within the
specified range.
These signals are 0 in the following case:
· When the current position along the controlled axis is not within the
specified range.
Signal
High–speed position
switch signal
HPS01 – HPS16
<Yxx#0 – Yxx+1#7>