B–63523EN–1/03
2. PREPARATIONS FOR OPERATION
407
14966 Maximum point of rectangle 2 of group C in the second axis
14967 Minimum point of rectangle 2 of group C in the second axis
[Data type] Two–word
Increment system IS–B IS–C Unit
Millimeter machine 0.001 0.0001 mm
Inch machine 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
These parameters set the maximum point and minimum point of rectangle
area 2 of group C in the second axis.
The set plane is specified with the group–A movement axes 1 and 2. Set
the distances from the machine zero point to the maximum and minimum
points.
Be sure to set a radius value regardless of whether the axis command is
a diameter– or radius–programmed command.
If there is no relevant rectangle area, set 0.
14968 Maximum point of rectangle 3 of group C in the first axis
14969 Minimum point of rectangle 3 of group C in the first axis
[Data type] Two–word
Increment system IS–B IS–C Unit
Millimeter machine 0.001 0.0001 mm
Inch machine 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
These parameters set the maximum point and minimum point of rectangle
area 3 of group C in the first axis.
The set plane is specified with the group–A movement axes 1 and 2. Set
the distances from the machine zero point to the maximum and minimum
points.
Be sure to set a radius value regardless of whether the axis command is
a diameter– or radius–programmed command.
If there is no relevant rectangle area, set 0.
[Unit of data]
[Unit of data]