
B–63523EN–1/03
12. DISPLAY/SET/EDIT
1591
(m) When the current torque data is indicated, the total time from the start
of store operation until the end of store operation is indicated. (When
store operation is currently continued, the total time until the current
time is indicated). When the sample data save function is enabled (bit
2 of parameter No. 6350 is set to 1), the total time since the start of
store operation for the sample data is also indicated.
When there are two or more target axes for fine torque sensing, you can
select a target axis for data display.
Press the [(OPRT)] and [AXIS] soft keys, and select a desired axis from
[ALL–AX], [1ST], [2ND], [3RD], and [4TH]. When [ALL–AX] is
selected, data on all the target axes is displayed. When single–axis display
is selected, and the sample data save function is enabled (bit 2 of
parameter No. 6350 is set to 1), sample data and latest data are displayed
at the same time.
When all–axes display is selected, and the sample data save function is
enabled (bit 2 of parameter No. 6350 is set to 1), the displayed data can
be switched between the sample data and latest data. Press the [(OPRT)]
soft key, then press [DATA+].
When single–axis display is selected, you can change the detection level.
In the graph, the detection level is displayed with a red horizontal line.
Press the [(OPRT)] then [DETECT] soft keys. To increase the detection
level, press [+1%] or [+10%]. To decrease the detection level, press
[–1%] or [–10%]. To end changing the detection level, press [END].
When the detection level is matched with the threshold value of the
abnormal load detection alarm (bit 4 of parameter No. 6350 is set to 1),
pressing [END] reflects the detection level in parameter No. 2104 (for
servo motors) or No. 4341 (for spindle motors). (Abnormal load
detection is a separate option.)
You can magnify and reduce the torque ratio (the vertical axis) and can
change its display position. Press the [(OPRT)] then [VERTCL]. Each
time you press [EXPANS], the torque ratio per graduation changes from
1%, 2.5%, 5%, 10%, 25%, 50%, 1%, ... Pressing [REDUCT] changes the
torque ratio in the opposite direction. To change the display position of
the graph, press [↑] or [↓]. Pressing [SET] terminates torque ratio change
operation, displaying the graph with a specified ratio at a specified
position.
You can magnify and reduce the time axis (the horizontal axis) and can
change its display position. Press the [(OPRT)] then [HORIZN]. Each
time you click [EXPANS], time per graduation is changed from 32 ms,
64 ms, 128 ms, 0.25 sec, 0.5 sec, 1 sec, 2.5 sec, 5 sec, 10 sec, 1 min, 2.5
min, 5 min, 10 min, 15 min, 0.5 h, 32 ms, ... Pressing [REDUCT] changes
time in the opposite direction. To change the display position of the
graph, press [←] or [→]. Pressing [SET] terminates time change
operation, displaying the graph with specified time at a specified position.
Operation
D Selecting an axis to be
displayed (selecting all
axes, the first axis,
second axis, third axis,
or fourth axis)
D Selecting displayed data
(only in all–axes display
mode; selection between
latest data and sample
data)
D Changing the detection
level (only in single–axis
display mode)
D Changing the torque
ratio (the vertical axis)
(magnification,
reduction, and display
position)
D Changing time (the
horizontal axis)
(magnification,
reduction, and display
position)