13. INPUT/OUTPUT OF DATA
1689
While an automation operation is being performed, a program input from
an I/O device connected to the reader/punch interface can be executed and
stored in memory.
Similarly, a program stored in memory can be executed and output
through the reader/punch interface at the same time.
(1)Search the head of a program (file) you want to run and input.
(2)Select the DNC operation mode.
(3)Set the input and run simultaneous mode select signal STRD to logical
1.
(4)Activate automatic operation.
(5)The system alternates between outputting one block and running one
block of data.
(1)Select a program you want to run and output.
(2)Select the DNC operation mode.
(3)Set the output and run simultaneous mode select signal STWD to
logical 1.
(4)Activate automatic operation.
(5)The system alternates between outputting one block and running one
block of data.
[Classification] Input signal
[Function] When this signal becomes logical 1, the control unit:
D Selects the input and run simultaneous mode.
To select the input and run simultaneous mode, it is necessary to
select the DNC operation mode and to set this signal to logical 1.
13.6
SIMULTANEOUS
INPUT AND OUTPUT
OPERATIONS
(M SERIES)
General
Basic procedure for input
and run simultaneous
operation
Basic procedure for output
and run simultaneous
operation
Signal
Input and run
simultaneous mode
select signal
STRD <G058#5>