B–63523EN–1/03
9. SPINDLE SPEED FUNCTION
1232
During simple spindle synchronous control, indications such as the
positional deviation of the first spindle are output in the usual way. For
the second spindle, however, only the positional deviation of the second
spindle is indicated in diagnostic data No. 415.
The positional deviation of the first spindle is indicated in diagnostic data
No. 414.
The absolute phase deviation between the first and second spindles is
indicated as a synchronization error in diagnostic data No. 414.
[Classification] Input signal
[Function] This signal specifies switching between simple spindle synchronous
control mode and ordinary spindle synchronous control mode when
simple spindle synchronous control is active.
[Operation] When this signal is set to 1, the control unit operates as follows:
– Enters simple spindle synchronous control mode.
[Classification] Input signal
[Function] This signal activates the parking function for the first spindle when simple
spindle synchronous control is active.
[Operation] When this signal is set to 1, the control unit operates as follows:
– Activates the parking function for the first spindle placed under simple
spindle synchronous control.
When the SPK bit (bit 7 of parameter No. 4800) is set to 1, #6 of G031
functions as this signal.
[Classification] Input signal
[Function] This signal activates the parking function for the second spindle when
simple spindle synchronous control is active.
D Positional deviation
display
Signal
Simple spindle
synchronous control
signal
ESRSYC<G064#6>
First spindle parking
signal
PKESS1<G122#6>
<G031#6>
Second spindle parking
signal
PKESS2<G122#7>
<G031#7>