13. INPUT/OUTPUT OF DATA
B–63523EN–1/03
1714
[Classification] Output signal
[Function] This signal instructs the Power Mate to perform data input/output based
on the I/O Link.
[Output condition] This signal is set to 1 in the following case:
– When data input/output is performed
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is IOLNK <G099#7/G251#0>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
[Classification] Output signal
[Function] This signal indicates that the CNC has started data output.
[Output condition] This signal is set to 1 in the following case:
– When data output is started
This signal is set to 0 in the following case:
– When data output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is EXRD <G098#1/G058#1>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
[Classification] Output signal
[Function] This signal forcibly terminates Power Mate data input/output.
[Output condition] This signal is set to 1 in the following cases:
– When the CNC issues an alarm
– When data input/output function B based on the I/O Link is used, and
external read/punch stop signal EXSTP is set to 1
This signal is set to 0 in the following case:
–When data input/output is terminated
This signal is a Power Mate control signal. The corresponding Power
Mate side signal is EXSTP <G098#2/G058#2>.
(The former address is for Power Mate A/B/C/E and the latter address is
for Power Mate D/H/i–D/i–H.)
Slave I/O Link selection
signal
IOLNK <F177#0>
Slave external read start
signal
ERDIO <F177#1>
Slave read/write stop
signal
ESTPIO <F177#2>