15. PMC CONTROL FUNCTION
B–63523EN–1/03
1878
6095 The number of programs used by the macro call function
[Data type] Byte
[Unit of data] Number
[Valid data range] 0 to 16
Specify the number of programs used by the macro call function.
For instance, when three is set, macro call start signal MCST1, MCST2,
and MCST3 become effective.
When ”0” is specified, this function becomes invalid.
6096 The first O number of the program used by the macro call function
[Data type] Word
[Unit of data] Number
[Valid data range] 1 to 9999
Specify the first O number of the program used by the macro call function.
For instance, when 9000 is set, the relation between the MCSTx signal
and the started program is as follows.
MCST1 signal : O9000 is called
MCST2 signal : O9001 is called
::
MCST16 signal : O9015 is called
6097 The first address of the signal group of the macro call function
[Data type] Word
[Unit of data] Number
[Valid data range] 0 to 65535
Specify the first address of the signal group of the macro call function.(R
signal)
For instance, when 500 is set, R500––R506 is used as a signal of the
macro call function.
When the number which does not exist is specified, this function becomes
invalid.
Number Message Contents
059 PROGRAM NUMBER
NOT FOUND
The program of the specified O number
is not registered in the memory.
5306 MODE CHANGE ERROR The mode is not correctly changed at
start of sequence.
Parameter
Alarm and message