B–63523EN–1/03
3. MANUAL OPERATION
531
The following table lists the relationships between each manual handle
feed travel distance select signal valid for an individual manual pulse
generator and the parameter No. for specifying its magnification.
State of bit 5 of
parameter
Valid manual handle
travel distance
Parameter for setting a magnification
No. 7100 (MPX
select signals
Mn Nn
If MPX = 0 First to fourth pulse generators MP1, MP2 No.7113 No.7114
First pulse generator MP1, MP2 No.7113 No.7114
Second pulse generator MP21, MP22 No.7131 No.7132
Third pulse generator MP31, MP32 No.7133 No.7134
Fourth pulse generator MP41, MP42 No.7135 No.7136
The following table lists the distance through which the tool travels at one
pulse from a manual pulse generator.
Manual handle feed travel distance
select signal
Travel distance at
handle–synchronous feed
MP2
MP22
MP32
MP42
MP1
MP21
MP31
MP41
Tool’s travel distance per pulse
from a manual pulse generator
0 0 Least input increment 1
0 1 Least input increment 10
1 0 Least input increment Mn
1 1 Least input increment Nn
#7
FC01404
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
FC0 Specifies the behavior of the machine tool when a block (G01, G02, G03,
etc.) containing a feedrate command (F command) that is 0 is issued
during automatic operation, as follows:
0 : A P/S alarm (No. 011) is displayed, and the block is not executed.
1 : No alarm is displayed, and the block is executed.