6. SETTING B-62994EN/02
-134-
• Searching for a custom macro variable
To find the desired custom macro variable, press the soft
key and specify a desired variable number.
• Incremental input
To perform incremental input, press the soft key.
For an explanation of the other functions, see the description below.
The custom macro common variables can also be input and output by an
external input/output device.
For details, see Section 7.4, "Data Input/Output."
6.4.1 Displaying local variables
Custom macro local variables can be displayed.
The variable numbers range from #1 to #33.
The variables cannot be set on this screen.
Procedure
1. When the [Custom Macro Variables] screen is currently not displayed,
follow the procedure described in Section 6.4, "Custom Macro Variable
Settings" to display the [Custom Macro Variables] screen.