l Protect
Specify whether to enable or disable data write. Data write operation is
enabled or disabled by making the following settings:
0: Enables data write.
1: Disables data write.
l Type
Set a data type. The settings correspond to the data types as follows:
0: Byte type
1: Word type
2: Long type
l Data
Set the total number of data items.
7.17.2 Setting the group data of PMC data
This section describes how to set the group data of PMC data.
Procedure
1. If the [PMC Data] screen is currently not displayed, display the [PMC
Data] screen as explained in Section 7.17 "Setting PMC Data."
NOTE
Before the group data of PMC data can be set, the data table must be
collected. For an explanation of data table setting, see Section
7.17.1, "Setting the data table of PMC data."