APPENDIX 1 REQUIRED NC SETTING FOR EACH BASIC OPERATION PACKAGE 1 SCREEN B-62994EN/02
-412-
Spindle Tuning Parameter
Changed by the “Operation”.
Contents Condition
Proportional gain Basic
Integral gain Basic
Loop gain Except “Speed Control” mode
Motor voltage Basic
ORAR gain “Orientation” mode
Regenerative power
Stop position shift
Acc./Dcc.time constant
ZRN gain
“Speed Control” mode
“Orientation” mode
“Sync. Control” mode
Except the above-mentioned
kinds of “Operation”
Reference point shift Except “Speed Control” mode
* One of “Regenerative power”, “Stop position shift”, “Acc./Dcc.
time constant”, “ZRN gain” is displayed according to the “Operation”.
Position error 1
Changed by the “Operation”.
Contents Condition
Not displayed “Speed Control” mode
Position error S1 “Sync. Control” mode
Position error S Except the above-mentioned kinds of
“Operation”
Position error 2
Changed by the “Operation”.
Contents Condition
Position error Z “Rigid Tapping” mode
Position error S2 “Sync. Control” mode
Not displayed Except the above-mentioned kinds of
“Operation”
Sync. error
Displayed only when the “Operation” is “Sync. Control” or ”Rigid
Tapping”.
Spindle Setting Parameter
Changed by the selected spindle.
Contents Condition
Gear ratio Basic
Max motor speed Basic
Max C axis speed Selected main
Max spindle speed Write protected